Biopolym. Cell. 1986; 2(5):256-261.
Structure and Function of Biopolymers
Use of isotachophoresis at a constant voltage for determination of mobility
1Zhukov M. Yu., 2Korol L. E.
  1. M. A. Suslov Rostov State University
    Rostov, USSR
  2. Institute of Molecular Biology and Genetics, Academy of Sciences of the Ukrainian SSR
    Kiev, USSR

Abstract

The simple experimental procedure which permits determining the dependence of electro-phoretic mobility of substances on pH of the solution is described. The absence of experimental data on such dependences considerably delays the progress of electrophoretic methods and their use for analyzing separating biopolymers.

References

[1] Carchon H, Eggermont E. Isotachophoretic determination of relative apparent mobility as an estimate of electrophoretic mobility of ions. Electrophoresis. 1982;3(5):263-274.
[2] Ilaglund H. Isotachophoresis. Sci. Tools. 1970. 17, N 1:9-13.
[3] Routs R. T. Electrolyte systems in isotachophoresis and their application to some proteins separation. Solna: Solna Skriv, 1971. 137 p.
[4] Zhukov MYu, Yudovich VI. Mathematical model of isotachophoresis. Dokl. Akad Nauk SSSR. 1982; 267(2): 334-338.
[5] Zhukov MYu. Nonstationary model Izotachophoresis. Zhurnal vychislitel'noy matematiki i matematicheskoy fiziki. 1984; (4):549-565.
[6] Babskiy VG, Zhukov MYu, Yudovich VI. Mathematical Theory of electrophoresis. Kiev, Naukova dumka, 1983; 203 p.
[7] Troughs I., J. Dvorak, Bogachkova V. Electrochemistry. Moscow, Mir, 1975; 472 p.
[8] Korol' LE, Kon'shin II, Azhitskiy GYu, Andriyenko VI. Universal installation for liquid column electrophoresis of biopolymers. Molekulyarnaya biologiya, 1984; Is. 36: 70-71.