Abstract

A new improved technology for manufacturing microelectrodes based on carbon fibres has been developed. The microelectrodes produced are long living, stable to electrochemical and chemical treatment. The electrochemically activated microelectrodes demonstrated high sensitivity to H2O2 with the detection limit for hydrogen peroxide of 0.5 μM. The microbiosensors based on carbon fibre microelectrodes have been developed for the determination of glucose, acetylcholine and choline concentration. They demonstrate high sensitivity in model solutions. The detection limits for glucose, acetylcholine and choline are of 60 uM, 1 uM u 1 uM respectively, that permits these microbiosensors to be applied for in vivo analysis of these substrates in mammalian brain.

References

[1] Norberg K. Changes in the cerebral metabolism induced by hyperventilation at different blood glucose levels. J Neurochem. 1976;26(2):353-9.
[2] Oldendorf WH, Stoller BE. Rat brain free glucose and lactate measurement by a novel method using bisecting decapitation-extrusion and enzyme denaturation at five seconds. J Neurochem. 1991;56(2):611-4.
[3] Netchiporouk LI, Shram NF, Jaffrezic-Renault N, Martelet C, Cespuglio R. In vivo brain glucose measurements: differential normal pulse voltammetry with enzyme-modified carbon fiber microelectrodes. Anal Chem. 1996;68(24):4358-64.
[4] Kenausis G, Chen Q, Heller A. Electrochemical glucose and lactate sensors based on "wired" thermostable soybean peroxidase operating continuously and stably at 37 degrees C. Anal Chem. 1997;69(6):1054-60.
[5] Fisher A, Hanin I, Lachman C. Alzheimer's and Parkinson's diseases: Strategies for research and development. New York: Plenum press, 1986.
[6] Guyenet PG, Javory AF, Beaujouan JC, Rossier BJ, Glowinski J. Effects of dopaminergic receptor agonists and antagonists on the activity of the neo-striatal cholinergic system. Brain Res. 1975;84(2):227-44.
[7] Haubrich DR, Gerber N, Pflueger AB, Zweig M. Tissue choline studied using a simple chemical assay. J Neurochem. 1981;36(4):1409-17.
[8] Roisin MP, Brassart JL, Charton G, Crepel V, Ben Ari Y. A new method for the measurement of endogenous transmitter release in localized regions of hippocampal slices. J Neurosci Methods. 1991;37(2):183-9.
[9] Kissinger PT. Microdialysis in Neuroscience. Eds T. E. Robinson, J. B. Justice. Amsterdam: Elsevier, 1991: 103-115.
[10] Tamiya E. Ultramicro acetylcholine sensor based on an enzyme-modified carbon fibre electrode. Anal Chimica Acta. 1991;250(2):129–34.
[11] Shram NF, Netchiporouk LI, Martelet C, Jaffrezic-Renault N, Bonnet C, Cespuglio R. In vivo voltammetric detection of rat brain lactate with carbon fiber microelectrodes coated with lactate oxidase. Anal Chem. 1998;70(13):2618-22.
[12] Rogers KJ, Slater P. Brain acetylcholine and monoamines during experimental catatonia. J Pharm Pharmacol. 1971;23(2):135-7.
[13] Tucek S. Problems in the organization and control of acetylcholine synthesis in brain neurons. Prog Biophys Mol Biol. 1984;44(1):1-46. Review.
[14] Larsson N, Ruzgas T, Gorton L, Kokaia M, Kissinger P, Csöregi E. Design and development of an amperometric biosensor for acetylcholine determination in brain microdialysates. Electrochim Acta. 1998;43(23):3541–54.
[15] Niwa O, Horiuchi T, Kurita R, Torimitsu K. On-line electrochemical sensor for selective continuous measurement of acetylcholine in cultured brain tissue. Anal Chem. 1998;70(6):1126-32.